EVALUATION OF THE EQUIVALENT LENGTH OF GLOBE AND GATE VALVES FROM DIFFERENT MANUFACTURERS IN A BENCH-SCALE UNIT
Main Article Content
Abstract
This study experimentally evaluated the equivalent lengths (Leq) and head losses of manual gate and globe valves from Mipel and Deca, installed on a bench with 1/2" PVC piping and water flow. Flow rates were determined using the volumetric method, while pressure differences were measured with piezometers and analyzed based on the mechanical energy balance. The results were compared with the parameters established by ABNT NBR 5626. The valves exhibited higher head losses than those predicted by the standard, suggesting that tabulated data may not fully represent actual operating conditions.
Downloads
Download data is not yet available.
Article Details
Section
Artigos

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.