Raman spectroscopy as a quality control tool for automotive engine coolant fluids
Main Article Content
Abstract
This study evaluated five automotive coolants commercially available in Santos, SP, Brazil, classified according to the ABNT NBR 14261:2016 standard using Raman spectroscopy. Two type A fluids (monoethylene glycol-based), two type C fluids (glycerin-based), and one glycol-free anticorrosive fluid were analyzed. The acquired spectra were compared with those of monoethylene glycol, glycerin, and anticorrosive additive standards. The types of additives present in the samples could be identified, revealing inconsistencies between product labeling and chemical composition. One type A product was found to contain a mixture with glycerin, while a type C product exhibited bands possibly associated with amines, despite declaring the absence of this component. In addition, one type A product showed no detectable Raman signals attributable to anticorrosive additives. These results demonstrate that Raman spectroscopy is an effective tool for supporting the quality control of automotive coolants, enabling the verification of their chemical composition and the identification of potential nonconformities in commercially available products.
Downloads
Article Details
Section

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.