Assessment of the Compaction Characteristics of Saturated Pellet Feed Deposited on a Water Column
Main Article Content
Abstract
This study investigated the compaction of saturated iron ore pellet feed, comparing the influence of the presence of a bottom water column (10% of the total height). A reduced-scale experimental setup equipped with a vibration device was used to enable load compaction. Three acrylic towers subjected to upward mechanical impacts and a standard mass of 5 kg of ore were employed. The results showed that the bottom water significantly increased the average compaction, from 16.04% (saturated condition only) to 39.55%. The bottom water rapidly percolated upward, reaching the top within the first minute of the test and accumulating an average upper water layer of 34.5 mm (70% of the initial volume). It was concluded that the bottom water reduces air pockets and voids, thereby intensifying ore densification during compaction tests.
Downloads
Article Details
Section

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.